Mounting Options
8 configurations — click any option to enlarge
8 configurations — click any option to enlarge
Configure
Choose each specification for VECTOR Series - LED Hazardous Location Linear Light - C1D2/C2D1 to instantly generate a quote-ready part number.
Choose the lumen output / wattage required.
Match the site voltage range.
Select the hazardous location classification.
Set the beam angle best suited for the space.
Pick the preferred CCT.
Choose glass style.
Select how the fixture will be installed.
Optional add-ons to round out the build.
Select: Power, Voltage, Optics, Color Temperature, Lens, Mount Style
Models from other manufacturers that VECTOR Series - LED Hazardous Location Linear Light - C1D2/C2D1 can replace. Always confirm classification, output and mounting on the exact catalogue number before ordering.
Example LEDEX part number
Example configuration — build the exact number for your output, optics and mounting.
| Brand | Model | Part number | Class | Output |
|---|---|---|---|---|
| Eaton Crouse-Hinds (Champ / Pauluhn / Hazard-Gard) | Champ MLLALinear | on request | C1D2/C2D1 | 4,000–8,000 |
| Eaton Crouse-Hinds (Champ / Pauluhn / Hazard-Gard) | Pauluhn DLLALinear | on request | C1D2 | 4,000–8,000 |
| Eaton Crouse-Hinds (Champ / Pauluhn / Hazard-Gard) | Pauluhn SummitLinear | on request | C1D2/C2D1 | 13,000–25,000 |
| Eaton Crouse-Hinds (Champ / Pauluhn / Hazard-Gard) | Pauluhn PVLM (legacy)Linear (marine) | on request | C1D2 | n/a |
| Appleton (Emerson) | RigmasterLinear | on request | C1D2/C2D1 | 3,890–7,650 |
| Appleton (Emerson) | ViamasterLinear (nonmetallic) | on request | C1D2 | 2,200–7,800 |
| Dialight (SafeSite / ProSite) | SafeSite Linear (Low Profile)Linear | on request | C1D2 | 3,300–7,900 |
| Killark (Hubbell) | LAL / LALFPLinear | on request | C1D2/C2D1 | 2,272–16,467 |
| Nemalux | GSLinear (compact) | on request | C1D2 | 500–5,000 |
| Nemalux | BLLinear (vapor-tight) | on request | C1D2 | 2,500–4,400 |
| Nemalux | NLLinear (high-output) | on request | C1D2 | 3,970–14,313 |
| Raytec SPARTAN | SPARTAN Linear WL84 / WL168 / SpigotLinear | on request | C1D2 / Zone | 3,065–14,096 |
| Hazlux (ABB / Thomas & Betts) | WNL SeriesLinear | on request | C1D2/C2D1 | 3,970–14,313 |
| Hazlux (ABB / Thomas & Betts) | LGS SeriesLinear (compact) | on request | C1D2 | 559–2,289 |
| Hazlux (ABB / Thomas & Betts) | LE2 SeriesLinear | on request | C1D2/C2D1 | 5,480–10,960 |
| Holophane (Acuity Brands) | Petrolux EMXH LinearLinear | on request | C1D2/C2D2 | 3,000–18,000 |
Eaton Crouse-Hinds (Champ / Pauluhn / Hazard-Gard)
Champ MLLA
Linear
C1D2 linear → VECTOR
Eaton Crouse-Hinds (Champ / Pauluhn / Hazard-Gard)
Pauluhn DLLA
Linear
Eaton Crouse-Hinds (Champ / Pauluhn / Hazard-Gard)
Pauluhn Summit
Linear
high-output linear
Eaton Crouse-Hinds (Champ / Pauluhn / Hazard-Gard)
Pauluhn PVLM (legacy)
Linear (marine)
PVLM is a legacy/discontinued Pauluhn designation — searchers are seeking a replacement; map to VECTOR
Appleton (Emerson)
Rigmaster
Linear
Appleton (Emerson)
Viamaster
Linear (nonmetallic)
Dialight (SafeSite / ProSite)
SafeSite Linear (Low Profile)
Linear
Killark (Hubbell)
LAL / LALFP
Linear
Nemalux
GS
Linear (compact)
Nemalux
BL
Linear (vapor-tight)
Nemalux
NL
Linear (high-output)
Raytec SPARTAN
SPARTAN Linear WL84 / WL168 / Spigot
Linear
Hazlux (ABB / Thomas & Betts)
WNL Series
Linear
Hazlux (ABB / Thomas & Betts)
LGS Series
Linear (compact)
Hazlux (ABB / Thomas & Betts)
LE2 Series
Linear
Holophane (Acuity Brands)
Petrolux EMXH Linear
Linear
2 ft / 4 ft Div 2 linear → VECTOR
Brand and model names are trademarks of their respective owners, used for identification and cross-reference only. LEDEX is not affiliated with, authorized by, or endorsed by these manufacturers.
All equivalents by brand
UL is the certification organization. The NEC applies to U.S. installations; the CEC applies to Canadian installations. Open the record for the project country and verify the exact model, hazardous-location marking and applicable conditions.
Configuration-specific records
Documents can vary by catalogue number. Each request sends the product, your current configuration and the record type to our technical team.
Ask for instructions applicable to the selected model, mounting method and voltage.
Ask for the available dimensional drawing or 3D model for the exact catalogue number.
Ask for photometry matching the selected wattage, optics and fixture configuration.
Ask our team to assemble the available data sheets, drawings, photometry and certification records.
Related Models
Other LEDEX models worth comparing, with their classifications and output levels.
What engineers and distributors ask most often before specifying the VECTOR.
Question about a classification, a photometric layout, or a specific part number?
Talk to an application engineerApplications
The VECTOR is specified across these sectors. Always confirm the model's C2D1, C1D2 marking matches the site's authenticated area classification drawing.
Send us the area classification, mounting height and target light level. We'll confirm the full part number and can prepare a free photometric study.