LEDEX

Canadian Alternative to Raytec SPARTAN

Replacing a Raytec SPARTAN fixture? This cross-reference identifies candidate LEDEX series. Send the existing model, classification, and mounting height; we will compare the marking, optics, mounting, and available photometric data.

  • Canada-wide project support
  • UL & cUL certified models
  • Configuration support
  • Technical submittal support
Call (438) 230-1010
  • SPARTAN Linear WL84 / WL168 / Spigot

    Linear

    Part number
    on request
    Class
    C1D2 / Zone
    Output
    3,065–14,096
    LEDEX equivalent
    VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR
  • SPARTAN Flood (BL24 / FL / MPFL / HPFL)

    Flood

    Part number
    on request
    Class
    C1D2 / Zone
    Output
    2,426–34,000
    LEDEX equivalent
    TITANTITAN-48-U-2-30-WW-TG-TB5-GRFORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GR
  • SPARTAN Bay (MPBY / HPBY)

    High/Low Bay

    Part number
    on request
    Class
    C1D2 / Zone
    Output
    5,000–25,000
    LEDEX equivalent
    FORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GRVANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GR
  • SPARTAN Bulkhead BL24

    Bulkhead / Wall

    Part number
    on request
    Class
    C1D2 / Zone
    Output
    2,750–4,250
    LEDEX equivalent
    GUARDIANGUARDIAN-03-U-2-110-WW-TPL-FLM-GRJelly JarJELLY-01-U-2-110-WW-DFG-PD-GR

Brand and model names are trademarks of their respective owners, used for identification and cross-reference only. LEDEX is not affiliated with, authorized by, or endorsed by these manufacturers.

How to substitute a Raytec SPARTAN fixture

A Raytec SPARTAN catalogue number encodes a classification, an output, an optic and a mount. A valid substitution reproduces each of those from the Canadian record of the LEDEX model, not from an equivalence table. This is the check we run before confirming a candidate series.

  1. 1

    Marking

    Compare the Class, Division or Zone, the gas or dust group and the temperature code of the existing fixture with the marking of the exact LEDEX configuration. A C1D2 fixture does not replace a C1D1 one; Group D alone does not replace Group C.

  2. 2

    Output and photometrics

    Compare delivered lumens at the real mounting height using the LEDEX model's IES file, not wattage. HID-to-LED replacements usually need fewer lumens for the same maintained illuminance.

  3. 3

    Optic and mount

    Match the distribution (30° to 110° symmetric, Type I to IV) and the bracket: pendant, trunnion, stanchion, wall or stem. Existing conduit entries and seals often decide the choice.

  4. 4

    Record and schedule

    Request the Canadian certification record for the complete LEDEX catalogue number, then write the full marking on the fixture schedule. The inspector compares markings, not series names.

LEDEX series are grouped by classification: Class 1 Division 1, Class 1 Division 2 and Class 2 Division 1.

LEDEX output by series

  • Jelly Jar LED Explosion Proof Low Bay & Area Light: 2,000–5,000 lm
  • VANGUARD: 6,000–9,000 lm
  • FORTRESS: 13,000–32,000 lm
  • TITAN: up to 60,000 lm (modular — two TITANs combined)