Canadian Alternative to Appleton (Emerson)
Replacing a Appleton (Emerson) fixture? This cross-reference identifies candidate LEDEX series. Send the existing model, classification, and mounting height; we will compare the marking, optics, mounting, and available photometric data.
- Canada-wide project support
- UL & cUL certified models
- Configuration support
- Technical submittal support
| Model | Part number | Class | Output | LEDEX equivalent |
|---|---|---|---|---|
| Mercmaster Gen 3High Bay / Task | on request | C1D2/C2D1 | 2,600–26,000 | FORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GRVANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GRJelly JarJELLY-01-U-2-110-WW-DFG-PD-GR by output: FORTRESS / VANGUARD / Jelly Jar |
| Mercmaster LED Low profileLow Bay / Task | on request | C1D2/C2D1 | 2,200–7,460 | VANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GRJelly JarJELLY-01-U-2-110-WW-DFG-PD-GR by output: VANGUARD / Jelly Jar |
| IHC LEDHigh Bay | on request | Industrial | 50,000–90,000 | ZENITHZENITH-16-U1-110-WW-TG-UB-BL by output: Zenith |
| BaymasterHigh/Low Bay/Flood light | on request | C1D2/C2D1 | 8,700–39,000 | TITANTITAN-13-U-1-30-WW-TG-PD-GRFORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GRVANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GR |
| Code-MasterHigh Bay | on request | C1D1 | 3,700–19,300 | RADIANTRADIANT-03-U-1-30-WW-TG-PD-GRTITANTITAN-13-U-1-30-WW-TG-PD-GR Div 1 high bay → TITAN |
| Wallmaster LED and IWH LEDWall Pack / Bulkhead / Low bay/ Area light | on request | C1D2/C2D1 | 3,500–12,000 | FORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GRVANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GRJelly JarJELLY-01-U-2-110-WW-DFG-PD-GR by output: FORTRESS / VANGUARD / Jelly Jar |
| Code-Master JrCompact / Task | on request | C1D1 | 1,600–5,150 | RADIANTRADIANT-03-U-1-30-WW-TG-PD-GR |
| Areamaster Gen 2Flood / High Bay / Area light | on request | C1D2/C2D1 | 9,500–38,000 | TITANTITAN-13-U-1-30-WW-TG-PD-GRTITANTITAN-48-U-2-30-WW-TG-TB5-GRFORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GR trunnion for high output |
| ContenderTask | on request | C1D2/C2D1 | 2,800–5,500 | Jelly JarJELLY-01-U-2-110-WW-DFG-PD-GR |
| A-51Task/Low bay | on request | C1D1 | 1,600–3,200 | RADIANTRADIANT-03-U-1-30-WW-TG-PD-GR |
| GlomasterJelly Jar / Bulkhead / Low Bay / Area light | on request | C1D2 | 1,000–5,000 | Jelly JarJELLY-01-U-2-110-WW-DFG-PD-GR |
| RigmasterLinear | on request | C1D2/C2D1 | 3,890–7,650 | VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR |
| Explosionproof RigmasterLinear | on request | C1D1 | 3,040–7,600 | SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR |
| ViamasterLinear (nonmetallic) | on request | C1D2 | 2,200–7,800 | VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR |
| HEX LEDExit / Emergency | on request | C1D2/C2 | egress | BEACONBEACON-02-U-EL-3-128-FLM-GR BEACON for the C1D2 tier only; no LEDEX equivalent for Class II |
| N2LEDEmergency | on request | C1D2 | 130–516 | BEACONBEACON-02-U-EL-3-128-FLM-GR |
Mercmaster Gen 3
High Bay / Task
- Part number
- on request
- Class
- C1D2/C2D1
- Output
- 2,600–26,000
by output: FORTRESS / VANGUARD / Jelly Jar
Mercmaster LED Low profile
Low Bay / Task
- Part number
- on request
- Class
- C1D2/C2D1
- Output
- 2,200–7,460
by output: VANGUARD / Jelly Jar
IHC LED
High Bay
- Part number
- on request
- Class
- Industrial
- Output
- 50,000–90,000
- LEDEX equivalent
- ZENITHZENITH-16-U1-110-WW-TG-UB-BL
by output: Zenith
Baymaster
High/Low Bay/Flood light
- Part number
- on request
- Class
- C1D2/C2D1
- Output
- 8,700–39,000
Code-Master
High Bay
- Part number
- on request
- Class
- C1D1
- Output
- 3,700–19,300
Div 1 high bay → TITAN
Wallmaster LED and IWH LED
Wall Pack / Bulkhead / Low bay/ Area light
- Part number
- on request
- Class
- C1D2/C2D1
- Output
- 3,500–12,000
by output: FORTRESS / VANGUARD / Jelly Jar
Code-Master Jr
Compact / Task
- Part number
- on request
- Class
- C1D1
- Output
- 1,600–5,150
- LEDEX equivalent
- RADIANTRADIANT-03-U-1-30-WW-TG-PD-GR
Areamaster Gen 2
Flood / High Bay / Area light
- Part number
- on request
- Class
- C1D2/C2D1
- Output
- 9,500–38,000
trunnion for high output
Contender
Task
- Part number
- on request
- Class
- C1D2/C2D1
- Output
- 2,800–5,500
- LEDEX equivalent
- Jelly JarJELLY-01-U-2-110-WW-DFG-PD-GR
A-51
Task/Low bay
- Part number
- on request
- Class
- C1D1
- Output
- 1,600–3,200
- LEDEX equivalent
- RADIANTRADIANT-03-U-1-30-WW-TG-PD-GR
Glomaster
Jelly Jar / Bulkhead / Low Bay / Area light
- Part number
- on request
- Class
- C1D2
- Output
- 1,000–5,000
- LEDEX equivalent
- Jelly JarJELLY-01-U-2-110-WW-DFG-PD-GR
Rigmaster
Linear
- Part number
- on request
- Class
- C1D2/C2D1
- Output
- 3,890–7,650
- LEDEX equivalent
- VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR
Explosionproof Rigmaster
Linear
- Part number
- on request
- Class
- C1D1
- Output
- 3,040–7,600
- LEDEX equivalent
- SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR
Viamaster
Linear (nonmetallic)
- Part number
- on request
- Class
- C1D2
- Output
- 2,200–7,800
- LEDEX equivalent
- VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR
HEX LED
Exit / Emergency
- Part number
- on request
- Class
- C1D2/C2
- Output
- egress
- LEDEX equivalent
- BEACONBEACON-02-U-EL-3-128-FLM-GR
BEACON for the C1D2 tier only; no LEDEX equivalent for Class II
N2LED
Emergency
- Part number
- on request
- Class
- C1D2
- Output
- 130–516
- LEDEX equivalent
- BEACONBEACON-02-U-EL-3-128-FLM-GR
Brand and model names are trademarks of their respective owners, used for identification and cross-reference only. LEDEX is not affiliated with, authorized by, or endorsed by these manufacturers.
How to substitute a Appleton fixture
A Appleton catalogue number encodes a classification, an output, an optic and a mount. A valid substitution reproduces each of those from the Canadian record of the LEDEX model, not from an equivalence table. This is the check we run before confirming a candidate series.
- 1
Marking
Compare the Class, Division or Zone, the gas or dust group and the temperature code of the existing fixture with the marking of the exact LEDEX configuration. A C1D2 fixture does not replace a C1D1 one; Group D alone does not replace Group C.
- 2
Output and photometrics
Compare delivered lumens at the real mounting height using the LEDEX model's IES file, not wattage. HID-to-LED replacements usually need fewer lumens for the same maintained illuminance.
- 3
Optic and mount
Match the distribution (30° to 110° symmetric, Type I to IV) and the bracket: pendant, trunnion, stanchion, wall or stem. Existing conduit entries and seals often decide the choice.
- 4
Record and schedule
Request the Canadian certification record for the complete LEDEX catalogue number, then write the full marking on the fixture schedule. The inspector compares markings, not series names.
LEDEX series are grouped by classification: Class 1 Division 1, Class 1 Division 2 and Class 2 Division 1.
LEDEX output by series
- Jelly Jar LED Explosion Proof Low Bay & Area Light: 2,000–5,000 lm
- VANGUARD: 6,000–9,000 lm
- FORTRESS: 13,000–32,000 lm
- TITAN: up to 60,000 lm (modular — two TITANs combined)