Canadian Alternative to Holophane (Acuity Brands)
Replacing a Holophane (Acuity Brands) fixture? This cross-reference identifies candidate LEDEX series. Send the existing model, classification, and mounting height; we will compare the marking, optics, mounting, and available photometric data.
- Canada-wide project support
- UL & cUL certified models
- Configuration support
- Technical submittal support
| Model | Part number | Class | Output | LEDEX equivalent |
|---|---|---|---|---|
| Petrolux PXHHHigh Bay | on request | C1D2/C2D1 | 12,000–28,000 | FORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GR round Div 2 high bay → FORTRESS |
| Petrolux PXLHLow Bay (round) | on request | C1D2/C2D1 | 3,000–10,000 | VANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GRJelly JarJELLY-01-U-2-110-WW-DFG-PD-GR by output: VANGUARD (mid) / Jelly Jar (compact) / FORTRESS for the 10,000 lm package |
| Petrolux EMXH LinearLinear | on request | C1D2/C2D2 | 3,000–18,000 | VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR 2 ft / 4 ft Div 2 linear → VECTOR |
| Predator HPFM (Medium)Flood | on request | C1D2 | 6,987–29,439 | FORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GRTITANTITAN-13-U-1-30-WW-TG-PD-GR Predator HPFS (small) covers the tier below |
| Predator HPFL (Large)Flood | on request | C1D2 | 24,669–44,389 | TITANTITAN-48-U-2-30-WW-TG-TB5-GRFORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GRTITANTITAN-13-U-1-30-WW-TG-PD-GR modular TITAN reaches ~60k lm |
| Wallpack IV Hazardous (HW4G)Wall Pack | on request | C1D2 | 3,398–7,027 | GUARDIANGUARDIAN-03-U-2-110-WW-TPL-FLM-GR |
| HXPLLinear (XP) | on request | C1D1 | 2,783–10,918 | SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR Div 1 Groups C & D; RADIANT for the low/mid packages, TITAN at the top |
| HRLL Predator Hazardous AreaArea (XP) | on request | C1D1 / Zone 1 | ~8,800 | RADIANTRADIANT-03-U-1-30-WW-TG-PD-GR |
| HEXFLow Bay / Flood (XP) | on request | C1D1 | 12,320–21,230 | TITANTITAN-13-U-1-30-WW-TG-PD-GRTITANTITAN-13-U-1-30-WW-TG-PD-GR trunnion/yoke mount → TITAN flood; pendant/ceiling → TITAN high bay |
| HEXF1Low Bay / Flood (XP) | on request | C1D1 | 2,470–8,510 | RADIANTRADIANT-03-U-1-30-WW-TG-PD-GR compact Div 1 low bay → RADIANT |
| HEXSLinear (XP) | on request | C1D1/C1D2 | 4,400–11,650 | SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR 2 ft / 4 ft Div 1 linear → SENTINEL |
| HEXSEMLinear + Emergency | on request | C1D1 | 9,550–10,260 | SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR Div 1 linear with integral battery → SENTINEL; VECTOR-EM is the Div 2 battery-backup equivalent |
| HETLinear (tubular, XP) | on request | C1D1 | 2,770–16,050 | SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR |
| HLEMCEmergency / Exit | on request | C1D2 | egress | BEACONBEACON-02-U-ESL-3-64-1-FLM-GRBEACONBEACON-02-U-EL-3-128-FLM-GR |
Petrolux PXHH
High Bay
- Part number
- on request
- Class
- C1D2/C2D1
- Output
- 12,000–28,000
- LEDEX equivalent
- FORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GR
round Div 2 high bay → FORTRESS
Petrolux PXLH
Low Bay (round)
- Part number
- on request
- Class
- C1D2/C2D1
- Output
- 3,000–10,000
by output: VANGUARD (mid) / Jelly Jar (compact) / FORTRESS for the 10,000 lm package
Petrolux EMXH Linear
Linear
- Part number
- on request
- Class
- C1D2/C2D2
- Output
- 3,000–18,000
- LEDEX equivalent
- VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR
2 ft / 4 ft Div 2 linear → VECTOR
Predator HPFM (Medium)
Flood
- Part number
- on request
- Class
- C1D2
- Output
- 6,987–29,439
Predator HPFS (small) covers the tier below
Predator HPFL (Large)
Flood
- Part number
- on request
- Class
- C1D2
- Output
- 24,669–44,389
modular TITAN reaches ~60k lm
Wallpack IV Hazardous (HW4G)
Wall Pack
- Part number
- on request
- Class
- C1D2
- Output
- 3,398–7,027
- LEDEX equivalent
- GUARDIANGUARDIAN-03-U-2-110-WW-TPL-FLM-GR
HXPL
Linear (XP)
- Part number
- on request
- Class
- C1D1
- Output
- 2,783–10,918
- LEDEX equivalent
- SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR
Div 1 Groups C & D; RADIANT for the low/mid packages, TITAN at the top
HRLL Predator Hazardous Area
Area (XP)
- Part number
- on request
- Class
- C1D1 / Zone 1
- Output
- ~8,800
- LEDEX equivalent
- RADIANTRADIANT-03-U-1-30-WW-TG-PD-GR
HEXF
Low Bay / Flood (XP)
- Part number
- on request
- Class
- C1D1
- Output
- 12,320–21,230
trunnion/yoke mount → TITAN flood; pendant/ceiling → TITAN high bay
HEXF1
Low Bay / Flood (XP)
- Part number
- on request
- Class
- C1D1
- Output
- 2,470–8,510
- LEDEX equivalent
- RADIANTRADIANT-03-U-1-30-WW-TG-PD-GR
compact Div 1 low bay → RADIANT
HEXS
Linear (XP)
- Part number
- on request
- Class
- C1D1/C1D2
- Output
- 4,400–11,650
- LEDEX equivalent
- SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR
2 ft / 4 ft Div 1 linear → SENTINEL
HEXSEM
Linear + Emergency
- Part number
- on request
- Class
- C1D1
- Output
- 9,550–10,260
- LEDEX equivalent
- SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR
Div 1 linear with integral battery → SENTINEL; VECTOR-EM is the Div 2 battery-backup equivalent
HET
Linear (tubular, XP)
- Part number
- on request
- Class
- C1D1
- Output
- 2,770–16,050
- LEDEX equivalent
- SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR
HLEMC
Emergency / Exit
- Part number
- on request
- Class
- C1D2
- Output
- egress
Brand and model names are trademarks of their respective owners, used for identification and cross-reference only. LEDEX is not affiliated with, authorized by, or endorsed by these manufacturers.
How to substitute a Holophane fixture
A Holophane catalogue number encodes a classification, an output, an optic and a mount. A valid substitution reproduces each of those from the Canadian record of the LEDEX model, not from an equivalence table. This is the check we run before confirming a candidate series.
- 1
Marking
Compare the Class, Division or Zone, the gas or dust group and the temperature code of the existing fixture with the marking of the exact LEDEX configuration. A C1D2 fixture does not replace a C1D1 one; Group D alone does not replace Group C.
- 2
Output and photometrics
Compare delivered lumens at the real mounting height using the LEDEX model's IES file, not wattage. HID-to-LED replacements usually need fewer lumens for the same maintained illuminance.
- 3
Optic and mount
Match the distribution (30° to 110° symmetric, Type I to IV) and the bracket: pendant, trunnion, stanchion, wall or stem. Existing conduit entries and seals often decide the choice.
- 4
Record and schedule
Request the Canadian certification record for the complete LEDEX catalogue number, then write the full marking on the fixture schedule. The inspector compares markings, not series names.
LEDEX series are grouped by classification: Class 1 Division 1, Class 1 Division 2 and Class 2 Division 1.
LEDEX output by series
- Jelly Jar LED Explosion Proof Low Bay & Area Light: 2,000–5,000 lm
- VANGUARD: 6,000–9,000 lm
- FORTRESS: 13,000–32,000 lm
- TITAN: up to 60,000 lm (modular — two TITANs combined)