LEDEX

Canadian Alternative to Holophane (Acuity Brands)

Replacing a Holophane (Acuity Brands) fixture? This cross-reference identifies candidate LEDEX series. Send the existing model, classification, and mounting height; we will compare the marking, optics, mounting, and available photometric data.

  • Canada-wide project support
  • UL & cUL certified models
  • Configuration support
  • Technical submittal support
Call (438) 230-1010
  • Petrolux PXHH

    High Bay

    Part number
    on request
    Class
    C1D2/C2D1
    Output
    12,000–28,000
    LEDEX equivalent
    FORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GR

    round Div 2 high bay → FORTRESS

  • Petrolux PXLH

    Low Bay (round)

    Part number
    on request
    Class
    C1D2/C2D1
    Output
    3,000–10,000
    LEDEX equivalent
    VANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GRJelly JarJELLY-01-U-2-110-WW-DFG-PD-GR

    by output: VANGUARD (mid) / Jelly Jar (compact) / FORTRESS for the 10,000 lm package

  • Petrolux EMXH Linear

    Linear

    Part number
    on request
    Class
    C1D2/C2D2
    Output
    3,000–18,000
    LEDEX equivalent
    VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR

    2 ft / 4 ft Div 2 linear → VECTOR

  • Predator HPFM (Medium)

    Flood

    Part number
    on request
    Class
    C1D2
    Output
    6,987–29,439
    LEDEX equivalent
    FORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GRTITANTITAN-13-U-1-30-WW-TG-PD-GR

    Predator HPFS (small) covers the tier below

  • Predator HPFL (Large)

    Flood

    Part number
    on request
    Class
    C1D2
    Output
    24,669–44,389
    LEDEX equivalent
    TITANTITAN-48-U-2-30-WW-TG-TB5-GRFORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GRTITANTITAN-13-U-1-30-WW-TG-PD-GR

    modular TITAN reaches ~60k lm

  • Wallpack IV Hazardous (HW4G)

    Wall Pack

    Part number
    on request
    Class
    C1D2
    Output
    3,398–7,027
    LEDEX equivalent
    GUARDIANGUARDIAN-03-U-2-110-WW-TPL-FLM-GR
  • HXPL

    Linear (XP)

    Part number
    on request
    Class
    C1D1
    Output
    2,783–10,918
    LEDEX equivalent
    SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR

    Div 1 Groups C & D; RADIANT for the low/mid packages, TITAN at the top

  • HRLL Predator Hazardous Area

    Area (XP)

    Part number
    on request
    Class
    C1D1 / Zone 1
    Output
    ~8,800
    LEDEX equivalent
    RADIANTRADIANT-03-U-1-30-WW-TG-PD-GR
  • HEXF

    Low Bay / Flood (XP)

    Part number
    on request
    Class
    C1D1
    Output
    12,320–21,230
    LEDEX equivalent
    TITANTITAN-13-U-1-30-WW-TG-PD-GRTITANTITAN-13-U-1-30-WW-TG-PD-GR

    trunnion/yoke mount → TITAN flood; pendant/ceiling → TITAN high bay

  • HEXF1

    Low Bay / Flood (XP)

    Part number
    on request
    Class
    C1D1
    Output
    2,470–8,510
    LEDEX equivalent
    RADIANTRADIANT-03-U-1-30-WW-TG-PD-GR

    compact Div 1 low bay → RADIANT

  • HEXS

    Linear (XP)

    Part number
    on request
    Class
    C1D1/C1D2
    Output
    4,400–11,650
    LEDEX equivalent
    SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR

    2 ft / 4 ft Div 1 linear → SENTINEL

  • HEXSEM

    Linear + Emergency

    Part number
    on request
    Class
    C1D1
    Output
    9,550–10,260
    LEDEX equivalent
    SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR

    Div 1 linear with integral battery → SENTINEL; VECTOR-EM is the Div 2 battery-backup equivalent

  • HET

    Linear (tubular, XP)

    Part number
    on request
    Class
    C1D1
    Output
    2,770–16,050
    LEDEX equivalent
    SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR
  • HLEMC

    Emergency / Exit

    Part number
    on request
    Class
    C1D2
    Output
    egress
    LEDEX equivalent
    BEACONBEACON-02-U-ESL-3-64-1-FLM-GRBEACONBEACON-02-U-EL-3-128-FLM-GR

Brand and model names are trademarks of their respective owners, used for identification and cross-reference only. LEDEX is not affiliated with, authorized by, or endorsed by these manufacturers.

How to substitute a Holophane fixture

A Holophane catalogue number encodes a classification, an output, an optic and a mount. A valid substitution reproduces each of those from the Canadian record of the LEDEX model, not from an equivalence table. This is the check we run before confirming a candidate series.

  1. 1

    Marking

    Compare the Class, Division or Zone, the gas or dust group and the temperature code of the existing fixture with the marking of the exact LEDEX configuration. A C1D2 fixture does not replace a C1D1 one; Group D alone does not replace Group C.

  2. 2

    Output and photometrics

    Compare delivered lumens at the real mounting height using the LEDEX model's IES file, not wattage. HID-to-LED replacements usually need fewer lumens for the same maintained illuminance.

  3. 3

    Optic and mount

    Match the distribution (30° to 110° symmetric, Type I to IV) and the bracket: pendant, trunnion, stanchion, wall or stem. Existing conduit entries and seals often decide the choice.

  4. 4

    Record and schedule

    Request the Canadian certification record for the complete LEDEX catalogue number, then write the full marking on the fixture schedule. The inspector compares markings, not series names.

LEDEX series are grouped by classification: Class 1 Division 1, Class 1 Division 2 and Class 2 Division 1.

LEDEX output by series

  • Jelly Jar LED Explosion Proof Low Bay & Area Light: 2,000–5,000 lm
  • VANGUARD: 6,000–9,000 lm
  • FORTRESS: 13,000–32,000 lm
  • TITAN: up to 60,000 lm (modular — two TITANs combined)