LEDEX

Canadian Alternative to Nemalux

Replacing a Nemalux fixture? This cross-reference identifies candidate LEDEX series. Send the existing model, classification, and mounting height; we will compare the marking, optics, mounting, and available photometric data.

  • Canada-wide project support
  • UL & cUL certified models
  • Configuration support
  • Technical submittal support
Call (438) 230-1010
  • JR

    Area / Flood

    Part number
    on request
    Class
    C1D2
    Output
    2,000–5,000
    LEDEX equivalent
    Jelly JarJELLY-01-U-2-110-WW-DFG-PD-GRVANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GR
  • MR

    Area / Flood

    Part number
    on request
    Class
    C1D2
    Output
    3,000–6,000
    LEDEX equivalent
    VANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GRJelly JarJELLY-01-U-2-110-WW-DFG-PD-GR
  • XR

    High/Low Bay / Flood / Area Light

    Part number
    on request
    Class
    C1D2
    Output
    8,000–20,000
    LEDEX equivalent
    FORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GRVANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GR

    VECTOR when specified as linear

  • AR

    Flood (high-output)

    Part number
    on request
    Class
    C1D2
    Output
    10,000–48,000
    LEDEX equivalent
    FORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GR

    within modular TITAN's ~60k range

  • GS

    Linear (compact)

    Part number
    on request
    Class
    C1D2
    Output
    500–5,000
    LEDEX equivalent
    VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR
  • BL

    Linear (vapor-tight)

    Part number
    on request
    Class
    C1D2
    Output
    2,500–4,400
    LEDEX equivalent
    VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR
  • NL

    Linear (high-output)

    Part number
    on request
    Class
    C1D2
    Output
    3,970–14,313
    LEDEX equivalent
    VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR

Brand and model names are trademarks of their respective owners, used for identification and cross-reference only. LEDEX is not affiliated with, authorized by, or endorsed by these manufacturers.

How to substitute a Nemalux fixture

A Nemalux catalogue number encodes a classification, an output, an optic and a mount. A valid substitution reproduces each of those from the Canadian record of the LEDEX model, not from an equivalence table. This is the check we run before confirming a candidate series.

  1. 1

    Marking

    Compare the Class, Division or Zone, the gas or dust group and the temperature code of the existing fixture with the marking of the exact LEDEX configuration. A C1D2 fixture does not replace a C1D1 one; Group D alone does not replace Group C.

  2. 2

    Output and photometrics

    Compare delivered lumens at the real mounting height using the LEDEX model's IES file, not wattage. HID-to-LED replacements usually need fewer lumens for the same maintained illuminance.

  3. 3

    Optic and mount

    Match the distribution (30° to 110° symmetric, Type I to IV) and the bracket: pendant, trunnion, stanchion, wall or stem. Existing conduit entries and seals often decide the choice.

  4. 4

    Record and schedule

    Request the Canadian certification record for the complete LEDEX catalogue number, then write the full marking on the fixture schedule. The inspector compares markings, not series names.

LEDEX series are grouped by classification: Class 1 Division 1, Class 1 Division 2 and Class 2 Division 1.

LEDEX output by series

  • Jelly Jar LED Explosion Proof Low Bay & Area Light: 2,000–5,000 lm
  • VANGUARD: 6,000–9,000 lm
  • FORTRESS: 13,000–32,000 lm
  • TITAN: up to 60,000 lm (modular — two TITANs combined)