LEDEX

Explosion-Proof Push Button Stations (NEMA 7 + 4X)

Explosion-proof push-button control stations for Class I Division 1 and 2 and Class II Division 1 locations, with NEMA 7, NEMA 9 and NEMA 4X ratings on the listed configurations. Start/stop, emergency-stop mushroom, selector-switch and pilot-light operators are factory-assembled in copper-free aluminum housings with threaded conduit entries, so the station carries a complete hazardous-location marking rather than a field-built assembly. NEMA 7 describes the enclosure's ability to contain an internal ignition of a Class I gas; NEMA 4X adds watertight and corrosion-resistant performance for washdown and outdoor use. Neither replaces the Canadian approval mark and the Division or Zone marking that CEC Section 18 requires. Send the control schematic, the number and type of operators, the classification and the material requirement for a configured part number and its record.

  • Canada-wide project support
  • UL & cUL certified models
  • Configuration support
  • Technical submittal support
Call (438) 230-1010

Product catalog

Filter by classification and fixture type to narrow the range. Every model links to its full specifications, certification records and photometric files.

Classification

1 models shown

Typical Applications

  • Motor start/stop and emergency-stop stations at pumps, compressors and conveyors
  • Local control of mixers, agitators and paint-line equipment
  • Selector and pilot-light stations on skids and outdoor process units
  • Washdown and corrosive environments requiring NEMA 4X

Specifications at a glance

  • NEMA 7 (Class I) and NEMA 9 (Class II) ratings per model, NEMA 4X option
  • One to three operators: start/stop, E-stop, selector, pilot light
  • Copper-free aluminum bodies, threaded NPT entries, stainless hardware options
  • Class I Division 1, Division 2 and Class II Division 1 markings shown per model

Frequently Asked Questions

Common questions about explosion-proof push button stations (nema 7 + 4x) and hazardous location requirements.

NEMA 7 is an enclosure type rated for indoor Class I, Division 1 and 2 hazardous locations, Groups A, B, C or D as marked. The enclosure is designed to contain an internal explosion of the specified gas and to cool escaping gases below the ignition temperature of the surrounding atmosphere. It is an enclosure performance type under NEMA 250; the hazardous-location approval itself is the Class, Division and Group marking on the certified product.

Get your fixture schedule reviewed

Send the classification drawing, fixture schedule or lighting requirements. We will compare suitable models, applicable records and lead times before quoting.