LEDEX

Canadian Alternative to Eaton Crouse-Hinds (Champ / Pauluhn / Hazard-Gard)

Replacing a Eaton Crouse-Hinds (Champ / Pauluhn / Hazard-Gard) fixture? This cross-reference identifies candidate LEDEX series. Send the existing model, classification, and mounting height; we will compare the marking, optics, mounting, and available photometric data.

  • Canada-wide project support
  • UL & cUL certified models
  • Configuration support
  • Technical submittal support
Call (438) 230-1010
  • Champ VMVL

    High/Low Bay

    Part number
    on request
    Class
    C1D2/C2D1
    Output
    3,000–25,000
    LEDEX equivalent
    FORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GRVANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GRJelly JarJELLY-01-U-2-110-WW-DFG-PD-GR

    by output: FORTRESS (high) / VANGUARD (mid) / Jelly Jar (compact)

  • Champ FMVA

    Flood

    Part number
    on request
    Class
    C1D2/C2D1
    Output
    3,000–50,000
    LEDEX equivalent
    TITANTITAN-48-U-2-30-WW-TG-TB5-GRFORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GRRADIANTRADIANT-03-U-1-30-WW-TG-PD-GRVANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GR

    FORTRESS/VANGUARD w/ trunnion for 13,000+ lm; RADIANT / VANGUARD for lower output

  • Champ MLLA

    Linear

    Part number
    on request
    Class
    C1D2/C2D1
    Output
    4,000–8,000
    LEDEX equivalent
    VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR

    C1D2 linear → VECTOR

  • Hazard-Gard XPLA

    Linear

    Part number
    on request
    Class
    C1D1
    Output
    3,800–8,300
    LEDEX equivalent
    SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR

    Div 1 linear → SENTINEL

  • Hazard-Gard EVLLA

    High Bay / Area

    Part number
    on request
    Class
    C1D1
    Output
    ~5,000-13,000
    LEDEX equivalent
    TITANTITAN-13-U-1-30-WW-TG-PD-GRRADIANTRADIANT-03-U-1-30-WW-TG-PD-GR
  • Vaporgard V2L / V3L

    Low Bay / Compact

    Part number
    on request
    Class
    C1D2
    Output
    1,700–3,300
    LEDEX equivalent
    Jelly JarJELLY-01-U-2-110-WW-DFG-PD-GR
  • Vaporgard Pro P2L / P3L

    Low Bay / Compact

    Part number
    on request
    Class
    C1D2
    Output
    1,700–3,300
    LEDEX equivalent
    Jelly JarJELLY-01-U-2-110-WW-DFG-PD-GR
  • Pauluhn ZPLA

    Linear

    Part number
    on request
    Class
    C1D1
    Output
    3,800–8,300
    LEDEX equivalent
    SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR

    marine/offshore Div 1 linear

  • Pauluhn DLLA

    Linear

    Part number
    on request
    Class
    C1D2
    Output
    4,000–8,000
    LEDEX equivalent
    VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR
  • Pauluhn Summit

    Linear

    Part number
    on request
    Class
    C1D2/C2D1
    Output
    13,000–25,000
    LEDEX equivalent
    VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR

    high-output linear

  • Pauluhn DFLA

    Flood

    Part number
    on request
    Class
    C1D2/C2D1
    Output
    9,000–25,500
    LEDEX equivalent
    TITANTITAN-13-U-1-30-WW-TG-PD-GRFORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GR
  • Pauluhn PVLM (legacy)

    Linear (marine)

    Part number
    on request
    Class
    C1D2
    Output
    n/a
    LEDEX equivalent
    VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR

    PVLM is a legacy/discontinued Pauluhn designation — searchers are seeking a replacement; map to VECTOR

  • Light-Pak N2LPS

    Emergency

    Part number
    on request
    Class
    C1D2
    Output
    egress
    LEDEX equivalent
    BEACONBEACON-02-U-EL-3-128-FLM-GR
  • UX / Ex-Lite Exit

    Exit Sign

    Part number
    on request
    Class
    C1D2 / Zone 1
    Output
    n/a
    LEDEX equivalent
    BEACONBEACON-02-U-ESL-3-64-1-FLM-GR

    BEACON exit for the C1D2 tier only; no LEDEX equivalent for Zone 1

Brand and model names are trademarks of their respective owners, used for identification and cross-reference only. LEDEX is not affiliated with, authorized by, or endorsed by these manufacturers.

How to substitute a Eaton Crouse-Hinds fixture

A Eaton Crouse-Hinds catalogue number encodes a classification, an output, an optic and a mount. A valid substitution reproduces each of those from the Canadian record of the LEDEX model, not from an equivalence table. This is the check we run before confirming a candidate series.

  1. 1

    Marking

    Compare the Class, Division or Zone, the gas or dust group and the temperature code of the existing fixture with the marking of the exact LEDEX configuration. A C1D2 fixture does not replace a C1D1 one; Group D alone does not replace Group C.

  2. 2

    Output and photometrics

    Compare delivered lumens at the real mounting height using the LEDEX model's IES file, not wattage. HID-to-LED replacements usually need fewer lumens for the same maintained illuminance.

  3. 3

    Optic and mount

    Match the distribution (30° to 110° symmetric, Type I to IV) and the bracket: pendant, trunnion, stanchion, wall or stem. Existing conduit entries and seals often decide the choice.

  4. 4

    Record and schedule

    Request the Canadian certification record for the complete LEDEX catalogue number, then write the full marking on the fixture schedule. The inspector compares markings, not series names.

LEDEX series are grouped by classification: Class 1 Division 1, Class 1 Division 2 and Class 2 Division 1.

LEDEX output by series

  • Jelly Jar LED Explosion Proof Low Bay & Area Light: 2,000–5,000 lm
  • VANGUARD: 6,000–9,000 lm
  • FORTRESS: 13,000–32,000 lm
  • TITAN: up to 60,000 lm (modular — two TITANs combined)