Canadian Alternative to Dialight (SafeSite / ProSite)
Replacing a Dialight (SafeSite / ProSite) fixture? This cross-reference identifies candidate LEDEX series. Send the existing model, classification, and mounting height; we will compare the marking, optics, mounting, and available photometric data.
- Canada-wide project support
- UL & cUL certified models
- Configuration support
- Technical submittal support
| Model | Part number | Class | Output | LEDEX equivalent |
|---|---|---|---|---|
| SafeSite High BayHigh Bay | on request | C1D1/C1D2 | 11,000–41,300 | TITANTITAN-13-U-1-30-WW-TG-PD-GRFORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GR TITAN for Div 1 tier; FORTRESS for Div 2 |
| SafeSite Low BayLow Bay | on request | C1D2 | 4,000–16,800 | VANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GRJelly JarJELLY-01-U-2-110-WW-DFG-PD-GRFORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GR |
| SafeSite Area LightArea | on request | C1D1/C1D2 | 2,200–9,000 | RADIANTRADIANT-03-U-1-30-WW-TG-PD-GRVANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GRJelly JarJELLY-01-U-2-110-WW-DFG-PD-GR RADIANT for Div 1 tier |
| SafeSite Linear (Low Profile)Linear | on request | C1D2 | 3,300–7,900 | VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR |
| SafeSite Class I Div 1 LinearLinear | on request | C1D1 | 3,600–7,250 | SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR battery-backup option → SENTINEL / VECTOR-EM |
| SafeSite Linear Battery BackupLinear / Emergency | on request | C1D2 | ~7,000 | VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR |
| ProSite FloodlightFlood | on request | C1D2 | 12,000–65,000 | RADIANTRADIANT-03-U-1-30-WW-TG-PD-GRTITANTITAN-13-U-1-30-WW-TG-PD-GRTITANTITAN-48-U-2-30-WW-TG-TB5-GR modular TITAN reaches ~60k lm; for >60k, quote a multi-fixture layout |
| SafeSite Bulkhead / WallpackWall Pack / Bulkhead | on request | C1D2 / Zone | 3,000–6,500 | GUARDIANGUARDIAN-03-U-2-110-WW-TPL-FLM-GR |
| SafeSite Emergency / ExitEmergency / Exit | on request | C1D1/C1D2 | egress | BEACONBEACON-02-U-ESL-3-64-1-FLM-GRBEACONBEACON-02-U-EL-3-128-FLM-GR BEACON for the Div 2 tier only; no LEDEX equivalent for Div 1 |
SafeSite High Bay
High Bay
- Part number
- on request
- Class
- C1D1/C1D2
- Output
- 11,000–41,300
TITAN for Div 1 tier; FORTRESS for Div 2
SafeSite Low Bay
Low Bay
- Part number
- on request
- Class
- C1D2
- Output
- 4,000–16,800
SafeSite Area Light
Area
- Part number
- on request
- Class
- C1D1/C1D2
- Output
- 2,200–9,000
RADIANT for Div 1 tier
SafeSite Linear (Low Profile)
Linear
- Part number
- on request
- Class
- C1D2
- Output
- 3,300–7,900
- LEDEX equivalent
- VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR
SafeSite Class I Div 1 Linear
Linear
- Part number
- on request
- Class
- C1D1
- Output
- 3,600–7,250
- LEDEX equivalent
- SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR
battery-backup option → SENTINEL / VECTOR-EM
SafeSite Linear Battery Backup
Linear / Emergency
- Part number
- on request
- Class
- C1D2
- Output
- ~7,000
- LEDEX equivalent
- VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR
ProSite Floodlight
Flood
- Part number
- on request
- Class
- C1D2
- Output
- 12,000–65,000
modular TITAN reaches ~60k lm; for >60k, quote a multi-fixture layout
SafeSite Bulkhead / Wallpack
Wall Pack / Bulkhead
- Part number
- on request
- Class
- C1D2 / Zone
- Output
- 3,000–6,500
- LEDEX equivalent
- GUARDIANGUARDIAN-03-U-2-110-WW-TPL-FLM-GR
SafeSite Emergency / Exit
Emergency / Exit
- Part number
- on request
- Class
- C1D1/C1D2
- Output
- egress
BEACON for the Div 2 tier only; no LEDEX equivalent for Div 1
Brand and model names are trademarks of their respective owners, used for identification and cross-reference only. LEDEX is not affiliated with, authorized by, or endorsed by these manufacturers.
How to substitute a Dialight fixture
A Dialight catalogue number encodes a classification, an output, an optic and a mount. A valid substitution reproduces each of those from the Canadian record of the LEDEX model, not from an equivalence table. This is the check we run before confirming a candidate series.
- 1
Marking
Compare the Class, Division or Zone, the gas or dust group and the temperature code of the existing fixture with the marking of the exact LEDEX configuration. A C1D2 fixture does not replace a C1D1 one; Group D alone does not replace Group C.
- 2
Output and photometrics
Compare delivered lumens at the real mounting height using the LEDEX model's IES file, not wattage. HID-to-LED replacements usually need fewer lumens for the same maintained illuminance.
- 3
Optic and mount
Match the distribution (30° to 110° symmetric, Type I to IV) and the bracket: pendant, trunnion, stanchion, wall or stem. Existing conduit entries and seals often decide the choice.
- 4
Record and schedule
Request the Canadian certification record for the complete LEDEX catalogue number, then write the full marking on the fixture schedule. The inspector compares markings, not series names.
LEDEX series are grouped by classification: Class 1 Division 1, Class 1 Division 2 and Class 2 Division 1.
LEDEX output by series
- Jelly Jar LED Explosion Proof Low Bay & Area Light: 2,000–5,000 lm
- VANGUARD: 6,000–9,000 lm
- FORTRESS: 13,000–32,000 lm
- TITAN: up to 60,000 lm (modular — two TITANs combined)