Canadian Alternative to Killark (Hubbell)
Replacing a Killark (Hubbell) fixture? This cross-reference identifies candidate LEDEX series. Send the existing model, classification, and mounting height; we will compare the marking, optics, mounting, and available photometric data.
- Canada-wide project support
- UL & cUL certified models
- Configuration support
- Technical submittal support
| Model | Part number | Class | Output | LEDEX equivalent |
|---|---|---|---|---|
| VML-XHigh/Low Bay | on request | C1D2/C2D1 | 3,900–28,000 | FORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GRVANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GRJelly JarJELLY-01-U-2-110-WW-DFG-PD-GR by output: FORTRESS / VANGUARD / Jelly Jar |
| MBL-XCompact Low Bay | on request | C1D2 | 910–6,139 | Jelly JarJELLY-01-U-2-110-WW-DFG-PD-GRVANGUARDVANGUARD-07-U-2-110-WW-TG-PD-GR |
| EMLHigh/Low Bay (XP) | on request | C1D1 | 2,880–5,900 | RADIANTRADIANT-03-U-1-30-WW-TG-PD-GR |
| EZLHigh/Low Bay (XP) | on request | C1D1 | 5,512–12,720 | RADIANTRADIANT-03-U-1-30-WW-TG-PD-GRTITANTITAN-13-U-1-30-WW-TG-PD-GR |
| LAL / LALFPLinear | on request | C1D2/C2D1 | 2,272–16,467 | VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR |
| L1LLinear (XP) | on request | C1D1 | 7,000–14,000 | SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR |
| KFL / KFLH / KFL2HFlood / Area | on request | C1D2/C2D1 | 6,111–80,820 | TITANTITAN-48-U-2-30-WW-TG-TB5-GRFORTRESSFORTRESS-07-U-2-110-WW-TG-PD-GR modular TITAN to ~60k lm; KFL2H tops ~80k — quote multi-fixture for the highest tier |
| KF1LFlood (XP) | on request | C1D1 | 7,182–15,707 | TITANTITAN-13-U-1-30-WW-TG-PD-GR |
| KWPLWall Pack | on request | C1D2 | 4,000–11,000 | GUARDIANGUARDIAN-03-U-2-110-WW-TPL-FLM-GR |
| EBSEmergency / Exit | on request | C1D2 | egress | BEACONBEACON-02-U-ESL-3-64-1-FLM-GRBEACONBEACON-02-U-EL-3-128-FLM-GR |
VML-X
High/Low Bay
- Part number
- on request
- Class
- C1D2/C2D1
- Output
- 3,900–28,000
by output: FORTRESS / VANGUARD / Jelly Jar
MBL-X
Compact Low Bay
- Part number
- on request
- Class
- C1D2
- Output
- 910–6,139
EML
High/Low Bay (XP)
- Part number
- on request
- Class
- C1D1
- Output
- 2,880–5,900
- LEDEX equivalent
- RADIANTRADIANT-03-U-1-30-WW-TG-PD-GR
EZL
High/Low Bay (XP)
- Part number
- on request
- Class
- C1D1
- Output
- 5,512–12,720
LAL / LALFP
Linear
- Part number
- on request
- Class
- C1D2/C2D1
- Output
- 2,272–16,467
- LEDEX equivalent
- VECTORVECTOR-05-U-2-30-WW-TPL-PD-GR
L1L
Linear (XP)
- Part number
- on request
- Class
- C1D1
- Output
- 7,000–14,000
- LEDEX equivalent
- SENTINELSENTINEL-03-U-1-110-WW-TG-PD-GR
KFL / KFLH / KFL2H
Flood / Area
- Part number
- on request
- Class
- C1D2/C2D1
- Output
- 6,111–80,820
modular TITAN to ~60k lm; KFL2H tops ~80k — quote multi-fixture for the highest tier
KF1L
Flood (XP)
- Part number
- on request
- Class
- C1D1
- Output
- 7,182–15,707
- LEDEX equivalent
- TITANTITAN-13-U-1-30-WW-TG-PD-GR
KWPL
Wall Pack
- Part number
- on request
- Class
- C1D2
- Output
- 4,000–11,000
- LEDEX equivalent
- GUARDIANGUARDIAN-03-U-2-110-WW-TPL-FLM-GR
EBS
Emergency / Exit
- Part number
- on request
- Class
- C1D2
- Output
- egress
Brand and model names are trademarks of their respective owners, used for identification and cross-reference only. LEDEX is not affiliated with, authorized by, or endorsed by these manufacturers.
How to substitute a Killark fixture
A Killark catalogue number encodes a classification, an output, an optic and a mount. A valid substitution reproduces each of those from the Canadian record of the LEDEX model, not from an equivalence table. This is the check we run before confirming a candidate series.
- 1
Marking
Compare the Class, Division or Zone, the gas or dust group and the temperature code of the existing fixture with the marking of the exact LEDEX configuration. A C1D2 fixture does not replace a C1D1 one; Group D alone does not replace Group C.
- 2
Output and photometrics
Compare delivered lumens at the real mounting height using the LEDEX model's IES file, not wattage. HID-to-LED replacements usually need fewer lumens for the same maintained illuminance.
- 3
Optic and mount
Match the distribution (30° to 110° symmetric, Type I to IV) and the bracket: pendant, trunnion, stanchion, wall or stem. Existing conduit entries and seals often decide the choice.
- 4
Record and schedule
Request the Canadian certification record for the complete LEDEX catalogue number, then write the full marking on the fixture schedule. The inspector compares markings, not series names.
LEDEX series are grouped by classification: Class 1 Division 1, Class 1 Division 2 and Class 2 Division 1.
LEDEX output by series
- Jelly Jar LED Explosion Proof Low Bay & Area Light: 2,000–5,000 lm
- VANGUARD: 6,000–9,000 lm
- FORTRESS: 13,000–32,000 lm
- TITAN: up to 60,000 lm (modular — two TITANs combined)